Do you have issues with zero point instability and performance on your freeze dryer? The SPG5/6/7 range of Sapphire Capacitance Diaphragm Pressure Gauges features a single crystal sapphire pressure sensing element with excellent corrosion resistance, high temperature capability and mechanical properties. In addition, it detects static capacitance to achieve excellent measurement repeatability even in high temperature measurement environments. These self-heating diaphragm vacuum gauges use advanced signal processing technology to achieve temperature characteristics and linearity with minimal measurement error. Their sapphire sensor, formed using micromachining technology, enables compact size and light weight. * Helps improve quality* Vacuum gauges are often used in extremely harsh environments and are generally prone to offsets due to a variety of factors. Vacuum gauge offsets affect the controlled variable, which in turn affects the quality of the final product. Fortunately, SPG Sapphire Diaphragm Vacuum Gauges use a mechanism that prevents zero drift. * Helps improve productivity* Reduces equipment downtime and is equipped with features that reduce wasted time. * Helps improve processes* Enables visualisation of various types of information that previously could only be determined by changes in the pressure signal, helping to improve production processes. For advice or enquiries about these products, please contact your Azbil Europe contact.
Azbil Europe NV
Automation Machinery Manufacturing
Zaventem, Provincie Vlaams-Brabant 1,306 followers
Human-centered automation
About us
Azbil Europe NV is an overseas affiliate in Europe of Azbil Corporation and has been serving a wide range of industries in Europe with industrial automation and control products since 2001. In 2006, Yamatake Group formulated its new group philosophy and brand symbol of "azbil", reflecting our commitment to realize safety, comfort and fulfillment in people's lives and contribute to the global environment through "human-centered automation" https://www.azbil.com/index.html -Usage Policy https://www.azbil.com/policy.html -Guidelines on the Use of azbil Group Social Media https://www.azbil.com/socialmediapolicy.html
- Website
-
http://eu.azbil.com
External link for Azbil Europe NV
- Industry
- Automation Machinery Manufacturing
- Company size
- 11-50 employees
- Headquarters
- Zaventem, Provincie Vlaams-Brabant
- Type
- Public Company
- Founded
- 2001
- Specialties
- Flow meters, PID control, Sensors, Flow controllers, Calorie meters, Pressure sensors, Industrial automation, and Semiconductor
Locations
-
Primary
Bosdellestraat, 120/2
Zaventem, Provincie Vlaams-Brabant 1933, BE
-
Lilienthalstraße29
Hallbergmoos, Bayern 85399, DE
Employees at Azbil Europe NV
-
Efrem Neveux
I make sure your business-to-business products and services are offered in the most effective and efficient way. | Chocolate 🍫 & tea 🍵 lover | Tea…
-
Bernd Workowski
Key Account Manager at Azbil Europe NV German Branch
-
Maarten Maes
Finance Manager at Azbil Europe
-
Michael Obermayer MBA
Dynamic Professional, interested in technology and sharing experience.
Updates
-
You can find a better solution than using a position sensor to check the clamp status of the machining centre. There are two advantages to using our Model H3C Adjustable Proximity Sensor for clamp verification: 1. Two ON/OFF outputs allow 4-position confirmation, saving space and eliminating the need for expensive analogue input modules. 2. It can automatically set thresholds without programming. You can get a clear understanding by watching our video. https://lnkd.in/eiDvUpjv
-
We launched a new PID controller that combines user friendly operation and advanced functional solutions. Our technical engineer is excited to support you and discuss about the detail. Click here https://lnkd.in/eNQfUWGn and come to the inquiry form. #PID #Temperature #Flow #Pressure #Control #Technology #AzbilEurope
-
Accurate detection and management of chemical level is crucial in many industries, especially in Cleaning/Washing machine, Li-ion battery electrolyte pouring machine and Coater/Developer. Model HPF-T032/T034 are suitable for applications where automatic refilling of chemicals is required to maintain a constant level. The selection of different operation modes and the combination of two sensors enables fail-safe detection of upper and lower limit values even if a sensor breaks. This means you can automate liquid level management and improve the safety of your equipment. Watch the "03 Fail-safe detection" content of our video to learn more about how the Model HPF-T032/T034 can benefit your application. https://lnkd.in/ejHr2pwJ #Productivity #Technology #Manufacturing #Automation #Semiconductor #AzbilEurope
-
Azbil Europe NV has announced the appointment of Ippei Aota as the new Managing Director of Azbil Europe NV with effect from 1 April 2024. Ippei joined Azbil Corporation in 2003 and has been working for Azbil Europe NV since 2015. In this role, he is very familiar with the European markets.
-
Introducing our flow sensor Model MCS100 was developed to meet the need for shorter takt time in the semiconductor chip transfer process. by enabling high-speed adsorption confirmation. Designed as an alternative method for adsorption detection using pressure, the Model MCS100 addresses the critical need for dependable adsorption detection for semiconductor chip transfer process. Key Features - Rapid response time with flow measurement contributing to device acceleration Confirmation of adsorption by flow measurement does not require waiting for a pressure change. So the time from adsorption confirmation to transfer can be shortened. - Reverse flow measurement is available Not only chip adsorption, but also release confirmation by reverse flow measurement is possible. Read more about our flow sensor model MCS100. https://lnkd.in/d_UZkyW #AzbilEurope #Automation #Semiconductor #FlowSensor
-
Say goodbye to zero point instability and performance issues when using our Capacitance Diaphragm Gauge, Model SPG in your freeze dryer. Featuring a sapphire diaphragm for durability. As you can see from the graph, our sapphire diaphragm has strengths in pressure changes to provide consistent and accurate pressure measurements in Sterilisation In Place (SIP) and Clean In Place (CIP) processes. Trust our technology to keep your operations running smoothly! We offer innovative solutions to address the challenges of freeze dry processes with our Model SPG. Contact us today to discover how the Model SPG can take your performance to the next level! https://lnkd.in/dwSUhVdz #AzbilEurope #Automation #FreezeDry #CDG #Lyophilisation
Sapphire Capacitance Diaphragm Gauge Model SPG5_/6_/7_
azbil.com
-
Do you have issues with zero point instability and performance on your freeze dryer? Our Capacitance Diaphragm Gauge Model SPG, equipped with a sapphire diaphragm, offers high durability and it provides a solution to solve the problem. The graph in the picture shows that the Model SPG has strengths in resisting atmospheric pressure and vacuum cycles, which ensures consistent and accurate pressure measurements during Sterilisation In Place (SIP) and Clean In Place (CIP) processes in freeze dryers. Our commitment is to provide innovative solutions that address the unique challenges of freeze dry processes. Please contact us to learn more about how the Model SPG can enhance the performance of your freeze dry machine. We offer innovative solutions with Model SPG to address the challenges of freeze dry processes. Contact us today to discover how Model SPG can take your performance to the next level! https://lnkd.in/dwSUhVdz #AzbilEurope #Automation #FreezeDry #CDG #Lyophilisation
Sapphire Capacitance Diaphragm Gauge Model SPG5_/6_/7_
azbil.com
-
Did you know that vacuum is not an "empty space" but a space where the pressure is lower than atmospheric pressure? Even in Space, which is generally recognized as a vacuum, there is no complete nothingness. The properties of vacuum have been applied to various advanced technologies and other applications of vacuum technology that improve industrial technology and daily life, and our products also contribute to this field. But what specifically does "vacuum" have to do with us? You will understand as you read this document. #AzbilEurope #Automation #Technology #Science #Physics
-
Would you benefit from replacing the electronic scale used in your decontamination or sterilization equipment with a product that is smaller and more flexible? Our Micro Flow Rate Liquid Flow Meter Model F7M has a small and lightweight body and offers reliable flow measurement of H2O2 and flexibility of use. This video clearly shows the advantages of using the Model F7M instead of an electronic scale. https://lnkd.in/e2xGGtXr #AzbilEurope #Automation #FlowMeter #Sterilization